5-47. LOW TONE (50inch only)
Function
The external control equipment sets the Low toned of the plasma monitor.
Transmission Data
DFH 80H 60H 0CH 01H DATA00 CKS
| DATA00: | 01H: Mode1 |
|
| 02H: Mode2 |
ACK |
| |
|
| |
| 7FH 60H 80H 0CH 01H DATA00 CKS | |
| DATA00: | 01H: Mode1 |
|
| 02H: Mode2 |
5-48. COLOR TUNE
Function
External control equipment can adjust RGB each color which a plasma monitor wants to emphasize.
Transmission Data |
| |
| DFH 80H 60H 0DH | 07H DATA00 to DATA06 CKS |
| DATA00: RED | 00H: |
|
| : |
|
| 20H: 0 |
|
| : |
|
| 40H: +32 |
| DATA01: GREEN | 00H: |
|
| : |
|
| 20H: 0 |
|
| : |
|
| 40H: +32 |
| DATA02: BLUE | 00H: |
|
| : |
|
| 20H: 0 |
|
| : |
|
| 40H: +32 |
| DATA03: YELLOW | 00H: |
|
| : |
|
| 20H: 0 |
|
| : |
|
| 40H: +32 |
| DATA04: MAZENTA | 00H: |
|
| : |
|
| 20H: 0 |
|
| : |
|
| 40H: +32 |
| DATA05: CYAN | 00H: |
|
| : |
|
| 20H: 0 |
|
| : |
|
| 40H: +32 |
Company Restricted