DATA06: RESET

00H: OFF

 

 

01H: ON

 

ACK

7FH 60H 80H 0DH 00H CKS

5-49.GAMMA GAIN Data

Function

External control apparatus changes Gamma of a plasma monitor.

Transmission Data

DFH 80H 60H 13H 02H DATA00 DATA01 CKS

DATA00: GAMMA FLAG

01H: Gamma change

DATA01: GAMMA

00H: 1(GAMMA2.1)

 

01H: 2(GAMMA2.2)

 

02H: 3(GAMMA2.3)

 

03H: 4(GAMMA2.4)

ACK

7FH 60H 80H 13H 01H DATA00 CKS

DATA00: GAMMA FLAG 01H: Gamma change

5-50.Running Sense

Function

External control apparatus grasps the power supply state of a plasma monitor.

A plasma monitor is made to recognize connection of PC CONTROL.

Transmission Data

1FH 80H 60H 88H 00H CKS

ACK

7FH 60H 80H 88H 01H DATA CKS

DATA: Bit0: Connect Condition

0:No connection

1:Connected

Bit1 0: Fixed 1:-

Bit2: Power Status

0:POWER ON

1:POWER OFF (STANBY) Bit3 0: Fixed

Bit4 0: Fixed

Bit5 0: Fixed

Bit6 0: Fixed

Bit7 0: Fixed