PDxx01 | Page: 18 / 49 |
Document Version [1.0]
5-23. H. POSITION Gain Data
Function
The external control equipment changes the H. POSITION gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag | 03H |
DATA01: H.POSITION Gain Flag | 02H |
DATA02: H.POSITION Gain | 80H: |
| : |
| FFH: |
| 00H: 0 |
| 01H: +01 |
| : |
| 7FH: +127 |
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag | 03H |
DATA01: H.POSITION Gain Flag | 02H |
5-24. V. HEIGHT Gain Data
Function
The external control equipment changes the
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag | 03H |
DATA01: | 07H |
DATA02: | 00H: 0 |
| : |
| 40H: +64 |
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag | 03H |
DATA01: | 07H |
5-25. H. WIDTH Gain Data
Function
The external control equipment changes the
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
| DATA00: USER PICTURE Gain Flag | 03H |
| DATA01: | 08H |
| DATA02: | 00H: 0 |
|
| : |
|
| 40H: +64 |
ACK |
| |
| 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS | |
| DATA00: USER PICTURE Gain Flag | 03H |
| DATA01: | 08H |
Company Restricted