PDxx01

RS-232C Control Specification

Page: 36 / 49

Document Version [1.0]

5-51.OSM ORBITER

Function

In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out.

Transmission Data

DFH 80H 60H 5FH 01H DATA00 CKS

 

DATA00

01H: ORBITER ON

 

 

02H: ORBITER OFF

ACK

 

 

 

 

7FH 60H 80H 5FH 01H DATA00 CKS

 

DATA00

01H: ORBITER ON

 

 

02H: ORBITER OFF

5-52.Input Skip

Function

In a monitor's key "an input change", when there is no signal, it flies and shifts to the following channel.

Transmission Data

DFH 80H 60H 61H 01H DATA00 CKS

DATA00

01H: ON

 

02H: OFF

ACK

7FH 60H 80H 61H 01H DATA00 CKS

DATA00

01H: ON

 

02H: OFF

5-53.SERIAL No. Request

Function

External control apparatus read the serial number of the set recorded by EEPROM of a plasma display.

Transmission Data

1FH 80H 60H 15H 00H CKS

ACK

7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS

Even DATA00-DATA11 is set up as follows.

Setting value

00H-09H

:

0 - 9

 

96H

:

Blank

 

10H-29H

:

A-Z of Alphabet

Company Restricted

Page 36
Image 36