Ignore Preroll Commands
A minimum
This option is very seldom used; it allows preroll commands to be ignored and assumes that the operational preroll is 4 frames. Do not check this unless you experience problems with frame accuracy on recordings and playback transitions. Start with a setting of 4 frames on the automation system and adjust until you achieve proper timing.
Auto
Toggles Auto
Assigned Serial Ports
VDCP protocol provides for altering the mapping of Serial Port to Video Channel via control commands. Checking this option will lock the Serial Port to Video Channel ordering.
•When checked, any command received on a particular serial port will be used to control the like numbered video channel. This means that automation systems that use fixed or limited VDCP ID numbers can use any output to control any channel of the server.
•With this option checked, there is no requirement for a Port Open command to allow the automation to control the channel. With some systems, this can negate the requirement to restart the automation system when bringing the server online.
•Do not check this option when using controllers that communicate with all channels over a single serial port.
Communication Port Parameters
The serial data transfer parameters for the server are fixed and cannot be changed. These characteristics are common to all automation controllers:
Baud Rate | 38.4 K Baud |
|
|
Start Bits | 1 |
|
|
Data Bits | 8 |
|
|
Parity | Odd |
|
|
Stop Bits | 1 |
|
|