• Verify power is present at unit.

Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Problem

Possible Cause

Correction

 

Power outage

Verify power is present at unit.

Broil element shuts off

 

Verify that the circuit breaker is not

shortly after the start of self-

 

tripped.

clean operation. Bake and

 

Replace household fuse, but do not

broil functions operate

 

fuse capacity.

normally.

Control Error

See “Control Systems

 

 

Troubleshooting.”

 

No power to fan motor

Check for 120 VAC supplied at fan

 

 

motor. If no voltage is present,

 

 

check for broken or loose wiring

 

 

between fan motor and relay board.

Convection fan motor does

 

If voltage is present at fan motor,

not operate.

Failed fan motor or winding/frozen shaft

go to the next step.

 

Check motor winding for continuity.

 

 

Check for a frozen motor shaft.

 

 

Check for broken wiring between

 

 

motor and neutral terminal block.

 

Failed oven lamp

Check/replace lamp, if necessary.

 

Failed wiring

Check for broken, loose or dirty

 

 

connections.

Oven light does not operate.

Failed light socket

Check light socket for continuity.

 

Failed light plunger/switch

Check plunger/switch for continuity.

 

 

Check wiring diagram for

 

 

application.

 

Programming error

Shut off power to oven for five

Self-clean cycle not working.

 

minutes by switching off circuit

 

breaker. Reset circuit breaker and

 

 

 

 

try oven again.

 

Oven is self-cleaning

Allow cycle to complete.

 

Oven is still hot

Door will not unlock until unit has

Oven door will not unlock.

 

cooled to safe temperature. Do not

 

force door open, this will void

 

 

 

 

warranty. Blow cool air on door

 

 

latch area to quicken process.

 

Normal

Minor smoking and/or odor is

Oven smokes/odor first few

 

normal the first few times of oven

 

usage.

times of usage.

 

 

Ventilate area well and perform

 

 

 

 

self-clean cycle.

Failure Codes.

Electronically Controlled

See Testing Procedures for

 

diagnostic checks.

 

 

14

16023416

©2004 Maytag Services