Maytag MER6755ACB/S/W Testing Procedures, Component Testing, Maytag Services, 16023416, Results

Models: MER6775ACB/F/N/S/W MER6555ACW MER6755ACB/S/W MER6755AAB/Q/S/W MER6875AAB/F/N/Q/S/W MER6751AAB/Q/S/W MER6875ACB/F/N/S/W MER6555AAB/Q/W MER6775AAB/F/N/Q/S/W

1 85
Download 85 pages 18.45 Kb
Page 15
Image 15
Testing Procedures

Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Component Testing

Illustration

Component
Test Procedure

 

 

Results

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven light socket

Remove one wire from receptacle and

 

Indicates continuity with bulb screwed in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

test resistance of terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

..............Measure voltage at oven light

 

120 VAC, see wiring diagram for terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

identification.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If no voltage is present at oven light,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

check wiring or light switches.

4-turn

Coil elements

Remove element and measure

 

Continuity, if not replace.

5-turn

 

resistance across terminals

 

4-turn:

37 to 45 Approximately

(Model MER6555AA*)

 

 

 

5-turn:

23 to 27 Approximately

1200 W

Ribbon elements

Remove element and measure

 

Continuity. If not, replace.

2500 W

 

resistance across terminals

 

1200W: 45 to 49 Approximately

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2500W: 20 to 24 Approximately

2400 W/1100 W (Dual)

Ribbon elements

Remove element and measure

 

Continuity. If not, replace.

2700 W/1700 W (Dual)

 

resistance across terminals

 

1100W: 40 to 46 Approximately (Inner)

(Models MER6775AA*,

 

 

 

1300W:

47 to 54 Approximately (Outer)

MER6875AA*)

 

 

 

 

 

 

 

 

 

1700W: 30 to 36 Approximately (Inner)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000W: 53 to 59 Approximately (Outer)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2700 W (Single)

Ribbon elements

Remove element and measure

 

Continuity. If not, replace.

(Model MER6755AA*)

 

resistance across terminals

 

2700W: 19 to 23 Approximately

100 W (Warmer)

Ribbon elements

Remove element and measure

 

Continuity. If not, replace.

(Models MER6775AA*,

 

resistance across terminals

 

100W: 132 to 146 Approximately

MER6875AA*)

 

 

 

 

 

 

 

 

 

 

5 L1 3

Snap Action Infinite

Connect Volt-ohms meter to

 

 

Approximate

 

 

 

 

 

 

 

switch

H1 and H2.

 

 

Time On
Time Off

 

4 H2 L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the following for voltages at

 

LO

5%

95%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

MED (4-5) 35%

65%

 

 

 

 

 

 

LO, MED, HI:

 

HI

100%

0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

H1

 

H1 to H2

 

240 VAC, if not replace switch.

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bake element, Upper

Disconnect wire leads to element and

 

Approximately 31.0 , if not replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

measure resistance of terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure voltage at bake element

 

240 VAC, see wiring diagram for terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

identification. If no voltage is present at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bake element check wiring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bake element, Lower

Disconnect wire leads to element and

 

Approximately 21.3 , if not replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

measure resistance of terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure voltage at bake element

 

240 VAC, see wiring diagram for terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

identification. If no voltage is present at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bake element check wiring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Broil element, Upper

Disconnect wire leads to element and

 

Approximately 25.4 , if not replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

measure resistance of terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure voltage at broil element

 

240 VAC, see wiring diagram for terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

identification. If no voltage is present at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

broil element check wiring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Broil element, Lower

Disconnect wire leads to element and

 

Approximately 18.6 , if not replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

measure resistance of terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure voltage at broil element

 

240 VAC, see wiring diagram for terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

identification. If no voltage is present at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

broil element check wiring.

©2004 Maytag Services

16023416

15

Page 15
Image 15
Maytag MER6755ACB/S/W manual Testing Procedures, Component Testing, Maytag Services, 16023416, Illustration, Test Procedure