Maytag MER6775ACB/F/N/S/W 11 10 1, Testing Procedures, Maytag Services, 16023416, Test Procedure

Models: MER6775ACB/F/N/S/W MER6555ACW MER6755ACB/S/W MER6755AAB/Q/S/W MER6875AAB/F/N/Q/S/W MER6751AAB/Q/S/W MER6875ACB/F/N/S/W MER6555AAB/Q/W MER6775AAB/F/N/Q/S/W

1 85
Download 85 pages 18.45 Kb
Page 17
Image 17
11

Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Illustration/Component

 

Test Procedure

Control Panel Assembly

Continuity is indicated as follows:

 

1000

– 6600 for Cancel and

 

Warming Zone pads

 

1000

– 10000 for All other pads

Model MER6875A**

18

 

11

10

1

Pad

1

2

3

4

5

6

7

8

9

0

Lower Cancel

Upper Cancel

Convect Bake Delay Clock Favorite Lower Clean Upper Clean Lower Bake Lower Light

Upper Keep Warm Upper Light Autoset

Lower Keep Warm Conv Roast Lower Broil Upper Bake Timer 2

Cook & Hold

Upper Broil Timer 1 Toast Warm Zone

Results

Trace

Measurement

14 & 16

Continuity

16 & 17

Continuity

6

& 8

Continuity

6

& 7

Continuity

8

& 17

Continuity

7

& 14

Continuity

6

& 15

Continuity

5

& 14

Continuity

6

& 14

Continuity

8

& 14

Continuity

1

& 2 or 3

Continuity

11 & 12 or 13

Continuity

4

& 15

Continuity

6

& 16

Continuity

5

& 16

Continuity

5

& 7

Continuity

5

& 15

Continuity

7

& 16

Continuity

8

& 15

Continuity

7

& 15

Continuity

7

& 17

Continuity

15 & 16

Continuity

14 & 17

Continuity

8

& 16

Continuity

4

& 8

Continuity

4

& 5

Continuity

4

& 14

Continuity

4

& 7

Continuity

5

& 6

Continuity

14 & 15

Continuity

4

& 16

Continuity

7

& 8

Continuity

4

& 6 or 17

Continuity

Models MER6555A**, MER6751AA*, MER6755A**, MER6775A** Membrane and Overlay

©2004 Maytag Services

16023416

17

Page 17
Image 17
Maytag MER6775ACB/F/N/S/W manual 11 10 1, Testing Procedures, Maytag Services, 16023416, Test Procedure, Results, Trace