Maytag MER6555AAB/Q/W manual Troubleshooting Procedures, Control Systems Troubleshooting, Digit

Models: MER6775ACB/F/N/S/W MER6555ACW MER6755ACB/S/W MER6755AAB/Q/S/W MER6875AAB/F/N/Q/S/W MER6751AAB/Q/S/W MER6875ACB/F/N/S/W MER6555AAB/Q/W MER6775AAB/F/N/Q/S/W

1 85
Download 85 pages 18.45 Kb
Page 10
Image 10
Troubleshooting Procedures

Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

!CAUTION

Verify proper grounding before checking for trouble.

Be careful of the high voltage circuit.

Discharge the high voltage capacitor.

When checking the continuity of the switches or of the high voltage transformer, disconnect one lead wire from these parts and then check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.

Do not touch any part of the circuit on the printed circuit board, since static electric discharge may damage the control panel. Always touch yourself to ground while working on this panel to discharge any static charge built up on your body.

Control Systems Troubleshooting

Description of Error Codes

The Diagnostic Code Display Mode allows viewing of the error diagnostic codes.

Each error code consists of four digits. The following table describes the function of each digit.

Digit

 

 

Description

 

Primary System:

1

– Local to the control circuit board

1st

 

3

– Sensor or meat probe

 

 

4

– Control input

 

 

9

– Door lock

2nd

Measurable:

d – Diagnostic: measurable parameter

 

 

c – Control related, replace control

3rd

Secondary System: Sequential numbering

4th

Oven Cavity:

1

– Upper oven (or single cavity oven)

 

2

– Lower oven

 

 

c – Control specific

Diagnostic Code Display Mode is accessed via the Quick Test Mode. To view the last 5 error codes, enter the Quick Test Mode by pressing and holding the UPPER CANCEL and UPPER BROIL pads for 3 seconds within 5 minutes of power-up. Diagnostic Code Display Mode may be activated only when applying power to the control.

10

16023416

©2004 Maytag Services

Page 10
Image 10
Maytag MER6555AAB/Q/W manual Troubleshooting Procedures, Control Systems Troubleshooting, Description of Error Codes, Digit