SYMPTOM

CAUSE

 

REQUIRED ACTION

 

 

 

 

 

1. Remove fluorescent tube from its sockets. If you

Marquee lamp is intermittent

Faulty fluorescent

 

find cracks or darkened ends, install new lamp.

or non-functional

tube

 

Clean tube.

 

 

2.

Check continuity of both fluorescent tube

VGM (video game machine)

 

 

filaments.

starts and plays normally

 

3.

Verify that fluorescent tube operates by placing it

 

 

 

in working VGM.

 

Faulty lamp fixture

 

Verify that lamp pins make good connection with

 

 

 

socket contacts.

 

Faulty wiring

 

Measure fluorescent lamp AC voltages. Check

 

 

 

wiring and connector continuity from AC power

 

 

 

chassis to lamp assembly.

 

 

1. Check bottom and rear of cabinet for blocked

VGM operates normally

Obstructed fan

 

airflow.

 

 

2. Move VGM away from sources of heat.

Cabinet becomes warm after

 

3.

Turn off VGM power. Remove dust from vent

several hours of use

 

 

holes with high-power vacuum cleaner.

 

Faulty wiring

 

Check fan wiring and connectors.

 

 

 

 

 

Faulty fan

 

Check operation of all fans.

 

 

 

 

 

1. Check any assembly (RAM, ROM, Battery, etc.)

Error messages appear on

Faulty hardware

 

identified in error messages.

screen

 

2.

Call your authorized distributor for help with

 

 

 

unresolved screen messages.

Fan Location and Mounting

Troubleshooting 6-16