Video Troubleshooting Table, continued

 

SYMPTOM

CAUSE

 

REQUIRED ACTION

 

 

 

 

 

 

 

 

 

 

Check floppy drive for diskette. If you find disk,

VGM (video game machine)

Floppy disk in drive

 

eject it. Leave VGM power on. Turn off

 

doesn’t appear

 

 

computer. Wait for hard disk to stop spinning.

 

 

 

 

Turn on computer.

 

 

No audio

 

 

Loosen computer case lid thumbscrews and lift

 

 

Faulty wiring

 

off cover. Assure that hard drive ribbon cable

Power-up self-test runs

 

 

connector is fully seated into mating connector

 

 

 

 

on motherboard. Check hard drive power cable.

 

 

 

1. Verify that hard disk drive is correct for this

 

 

Improper components

 

VGM. Label on drive records manufacturer

 

 

 

 

name, assembly number and program version.

 

 

 

2. Verify that

circuit boards

are correct

for this

 

 

 

 

VGM. Label on each board

records

 

 

 

 

manufacturer name, assembly number and

 

 

 

 

hardware version.

 

 

 

 

 

3. Verify that ROM instruction set is correct for this

 

 

 

 

VGM. VGM set includes more than one ROM.

 

 

 

 

Label on each ROM records assembly number

 

 

 

 

and software version.

 

 

 

 

Hard drive problems

1. Turn computer on. Immediately look under hard

 

 

 

drive. Hard Drive Activity LED flashes if drive is

 

 

 

 

operating properly.

 

 

 

 

 

2. Allow VGM to load normally. Note and record

 

 

 

 

any error messages that occur during self-test.

 

 

 

3. Remove hard drive and install it in working VGM.

 

 

 

 

If symptom recurs there, hard drive is faulty.

 

 

 

 

Replace it.

 

 

 

 

 

Picture tube aperture

 

Remove diskettes from room. Demagnetize

Blotches of color appear on

mask is magnetized

 

monitor with external degaussing coil. Take care

 

screen

 

 

not to magnetize neighboring VGMs. Monitor

 

 

 

 

may be on or off for this procedure.

 

 

 

 

1.

Turn on VGM.

 

 

White areas in center of

Picture tube purity or

2.

Press and hold TEST MODE to enter Menu

 

screen appear tinged with

static convergence is

 

System. At Operator (Main) Menu, select

 

color

out of alignment

 

Diagnostic Menu. Then select Monitor Patterns

 

 

 

 

Menu. Run through Crosshatch, Red, Green and

Object edges have fringe of

 

 

Blue screens to find clearest display of problem.

 

one or more colors

 

3.

Display screen with greatest problem.

 

 

 

 

4. Display Crosshatch Screen. Locate purity and

 

 

 

 

static convergence ring magnets on back of

 

 

 

 

monitor neck. Watch screen in mirror. Adjust

 

 

 

 

magnets

to minimize

problem.

Follow

 

 

 

 

instructions from monitor manufacturer.

 

 

 

 

5.

Display Crosshatch Screen. Touch up

 

 

 

 

adjustments while watching screen in mirror.

CAUTION: Don’t operate the monitor without its Remote Adjustment Board.

WARNING: HANDLE FLUORESCENT TUBE AND CRT WITH CARE. If you drop a fluorescent tube or CRT and it breaks, it will implode! Shattered glass can fly eight feet or more from the implosion.

Troubleshooting 6-13