Midway 16-20044-101, 16-20040-101 manual Link Troubleshooting Table

Models: 16-20044-101 16-20040-101

1 105
Download 105 pages 39.56 Kb
Page 95
Image 95

Link Troubleshooting Table

SYMPTOM

CAUSE

 

 

REQUIRED ACTION

 

 

 

 

 

 

 

1. Don’t extend linking cables that come with VGM.

Can’t connect VGMs (video

Faulty wiring

2.

Install required crossover between VGM

game machines) together

 

 

cabinets. Each coupler connects two cabinets

 

 

 

(one pair). Don’t use standard telephone type

 

 

 

couplers or wiring to link cabinets.

 

 

 

 

3. Use only 10Base-T, Ethernet-type, Category 5,

 

 

 

twisted-pair wiring for VGM data.

 

 

 

 

 

Use required network hub for your local network.

 

Improper linking

 

Hub Link Kit permits up to four cabinet

 

hardware

 

connections. Cabinet array completion requires

 

 

 

basic kit brackets and spacers.

 

 

 

 

1. Record any error messages that occur during

VGM doesn’t recognize

Improper settings

 

self-test.

 

 

 

 

 

other players in linking

 

2.

From Operator (Main) Menu, choose

operation

 

 

Adjustments Menu. Then select Linked Play

 

 

 

Adjustments Menu. Assure that you’ve set

VGM functions normally by

 

 

LINKED PLAY to ON.

 

 

 

itself

 

3.

Be sure that each VGM has unique ID number.

 

Power problem

 

If hub is in use, verify that power is applied. AC

 

 

 

adapter wires are thin and easily damaged.

 

 

1. Inspect hub indicator lights. Each active port

 

Faulty wiring

 

should have illuminated indicator. If cable

 

(3 or more cabinets)

 

connects, and that position has no lit indicator,

 

 

 

check for cable continuity from hub to cabinet.

 

 

2. Assure

that

no loose wires catch

in

hinges,

 

 

 

doors, or under cabinet.

 

 

 

 

 

3. Verify

that

linking

cable connects

to

Network

 

 

 

Board at each VGM’s computer.

 

 

 

 

4. Verify that each linking cable operates properly

 

 

 

by placing it in working VGM.

 

 

 

 

 

1. Assure that switches on hub are set correctly

Some VGMs in group link

Improper hub switch

 

according to Hub Link Kit instructions.

properly, while others don’t

setting

 

(Networked cabinets don’t require couplers. Hub

 

 

 

has electronic crossover.)

 

 

 

 

 

2. Inspect hub indicator lights for link activity. See

 

 

 

manufacturer’s literature for diagnostics.

 

 

 

 

Verify that all linked cabinets use same software

 

Wrong software

 

version. Otherwise, linked cabinets won’t

 

version

 

recognize each other. Contact your distributor.

 

 

1. Insert crossover connections between coupled

 

Faulty wiring

 

cabinets. Standard couplers appear identical to

 

(2 cabinets)

 

devices supplied with cabinets, but don’t include

 

 

 

internal crossover.

 

 

 

 

 

 

2. Verify

that

each

linking

crossover

coupler

 

 

 

operates properly by placing it in working link

 

 

 

between two cabinets.

 

 

 

 

 

1. You used additional crossover connector and

 

Faulty wiring

 

cable to extend VGM or hub link connection.

 

(3 or more cabinets)

 

Two crossovers cancel and cause same

 

 

 

problem as no link crossover.

 

 

 

 

 

2.

Connect cables directly to hub. Don’t use

 

 

 

crossover coupler and hub together in single

 

 

 

network.

 

 

 

 

 

 

 

3. Separate communications

wiring

from other

 

 

 

wiring. Wires that must cross should cross at

 

 

 

right angles to limit noise pickup.

 

 

Troubleshooting 6-8

Page 95
Image 95
Midway 16-20044-101, 16-20040-101 manual Link Troubleshooting Table