Programming functions
DOS 3 (neutralizer)
Setting the neutralizer dosage
Set dosage concentration according to the neutralizer manufacturer's recommendations.
Step
^Press the 0 button until E02 appears in the display.
^Turn the program selector to "Intensive".
^Press and hold the ß button until the required value appears in the display, e.g., 0.2.
Display / Result
E02
The programmed dosage concentration appears in the display, e.g., 0.10 = 0.10 %
0.20The dosage concentration is now set.
Dosage concentration setting:
Priming the dosage system
The dosage system does not need to be primed (cleared of air) unless:
–the dosage concentration is being set for the first time,
–the neutralizer container was inadvertently completely emptied .
Step | Display / Result |
^ Press the 0 button until E02 appears in | E02 |
the display. |
|
^Turn the program selector to "Universal". d§3
^ Press the ß button. | The dosage system will be primed |
| automatically. Priming is complete |
| when 0 appears in the display. |
^Exit the programming mode. Start "Rinse" program.
This will rinse away any agents that entered the wash cabinet during priming.
38