DOS 3 (neutralizer)

Programming functions

DOS 3 (neutralizer)

Setting the neutralizer dosage

Set dosage concentration according to the neutralizer manufacturer's recommendations.

Step

^Press the 0 button until E02 appears in the display.

^Turn the program selector to "Intensive".

^Press and hold the ß button until the required value appears in the display, e.g., 0.2.

Display / Result

E02

The programmed dosage concentration appears in the display, e.g., 0.10 = 0.10 %

0.20The dosage concentration is now set.

Dosage concentration setting:

Priming the dosage system

The dosage system does not need to be primed (cleared of air) unless:

the dosage concentration is being set for the first time,

the neutralizer container was inadvertently completely emptied .

Step

Display / Result

^ Press the 0 button until E02 appears in

E02

the display.

 

^Turn the program selector to "Universal". d§3

^ Press the ß button.

The dosage system will be primed

 

automatically. Priming is complete

 

when 0 appears in the display.

^Exit the programming mode. Start "Rinse" program.

This will rinse away any agents that entered the wash cabinet during priming.

38

Page 38
Image 38
Miele G 7883 CD DOS 3 neutralizer, Programming functions, Setting the neutralizer dosage, Step, Display / Result