SECTION 3 − INSTALLATION
3-1. Specifications
Type of Input | Welding Power | Wire Feed | Wire Diameter | Welding | IP | Overall | Weight | |
Power | Source Type | Speed Range | Range | Circuit Rating | Rating | Dimensions | ||
| ||||||||
|
|
|
|
|
|
|
| |
| Constant Voltage (CV) |
| .030 To 1/16 in | 100 Volts, 400 |
| Length: |
| |
| DC For GMAW Or |
|
| (540 mm) | Net: 48 lb | |||
24 Volts AC |
| (0.8 To 1.6 mm) |
| |||||
Constant Voltage(CV) / | 70 To 875 ipm | Amperes, |
| Width: | (21.8 kg) | |||
|
| |||||||
Constant Current (CC) DC | (1.8 To 22.2 |
| 100% Duty | IP 23 |
| |||
3 Amperes | Max Spool | (241 mm) |
| |||||
For | mpm) | Cycle |
| Ship: 56 lb | ||||
50/60 Hertz | Capacity: 12 in |
| Height: 16 in | |||||
All Need |
|
|
| (24.5 kg) | ||||
|
| (305 mm) |
|
| ||||
| Contactor Control |
|
|
| (406 mm) |
| ||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
3-2. Typical Air-Cooled System Connections
1
Tools Needed:
9/16, 5/8, 3/4 in
2
11
3
4
5
6
10
7
8
1300/400 Ampere Model CC/CV Inverter Welding Power Source
.Use settings shown for both pulse MIG welding and MIG welding.
2450 Ampere Model CV Inverter Welding Power Source
System can be set up with a variety of conventional Constant Voltage (CV) welding power sources.
3
4Positive (+) Weld Cable
5Negative (−) Weld Cable
Select and prepare weld cables ac- cording to welding power source Owner’s Manual.
6Workpiece
7Voltage Sensing Lead (Optional Use)
8
9Wire Feeder
YDo not use gas pressure above 50 psi (345 kPa) or me- chanical gas valve in gun can leak.
10Gas Hose
11Gas Cylinder
Route hose from regulator/flowme- ter and connect to shielding gas valve fitting.
9
801 809 / Ref. 175 086 / Ref. 180