Miller Electric OM-1589 manual Teach Points Explained

Models: OM-1589

1 64
Download 64 pages 40.86 Kb
Page 38
Image 38

SECTION 10 − TEACH POINTS

10-1. Teach Points Explained

See GMAW-P (Pulsed MIG) Process Guide (MILLER Part No. 158 920) supplied with unit for more information.

Apk = Peak Amperage

The teach mode allows the user to create custom pulse programs. The teach mode has 15 teach points. At each teach point, the user can ad- just five parameters to shape the pulse waveform of the weld output. The five parameters are: IPM (MPM), Apk, Abk, PPS, and PWms.

Apk, Abk, PPS, and PWms acting together provide the energy neces- sary to burn off welding wire at a set wire feed speed. The graph below shows that as wire feed speed in- creases, energy increases (Apk, Abk, PPS, and PWms acting syn- ergically).

Abk = Background Amperage

PPS = Pulses Per Second

PWms = Pulse Width (Milliseconds)

IPM 875

 

 

 

 

 

 

 

820

 

 

 

 

 

 

 

765

 

 

 

 

 

 

 

710

 

 

 

 

 

 

 

655

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

545

 

 

 

 

 

 

 

490

 

 

 

 

 

 

 

435

 

 

 

 

 

 

 

380

 

 

 

 

 

 

 

325

 

 

 

 

 

 

 

270

 

 

 

 

 

 

 

215

 

 

 

 

 

 

 

160

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

Apk

100

180

210

240

270

300

330

Abk

10

20

30

40

50

60

70

PPS

20

55

80

105

130

160

185

PWms

1

 

 

 

2

 

 

Under some conditions, the wire feeder limits wire feed speed to maintain all pulse parameters with- in the capability of the system.

Example Of A Synergic

Setting For 525 IPM With

All Teach Points Set At 55

IPM Increments

360

370

420

450

480

510

540

565

Apk

80

90

100

110

120

130

140

200

Abk

210

235

260

290

315

340

365

400

PPS

3

 

 

4

 

 

 

5

PWms

OM-1589 Page 32