3-8. Front Panel Connections for Gun

Tools Needed:

5/8, 11/16, 1-1/8 in

Water-Cooled

Model Shown

4

5

6

3

2

1

Ref. 800 688-B

Water-Cooled Guns:

1 Gun Control Cable

Insert plug into Gun Control receptacle, and tighten threaded collar.

2 Gas Hose

Connect to Gas fitting on feeder.

3Power/Water Cable

4Strain Relief

Remove strain relief as shown.

Route cable through strain relief and connect

to Weld/Water From Gun outlet on feeder (left-hand threads). Reinstall strain relief.

5 Wire Conduit

Route through strain relief. Insert through front panel. Go to Section 3-6.

6 Water Hose

Connect to Water To Gun fitting on feeder (left-hand threads).

Air-Cooled Gun:

1 Gun Control Cable

Insert plug into Gun Control receptacle, and tighten threaded collar.

2 Gas Hose

Connect to Gas fitting on feeder.

3 Power Cable

Route cable through front panel and connect to power block. See Section 3-7.

4 Strain Relief

Remove strain relief as shown.

5 Wire Conduit

Route through strain relief. Insert through front panel. Go to Section 3-7.

OM-1589 Page 15

Page 21
Image 21
Miller Electric OM-1589 manual Front Panel Connections for Gun, Tools Needed 11/16, 1-1/8 Water-Cooled Model Shown