3-8. Front Panel Connections for Gun
Tools Needed:
5/8, 11/16, 1-1/8 in
Water-Cooled
Model Shown
4
5
6
3
2
1
Ref. 800
Water-Cooled Guns:
1 Gun Control Cable
Insert plug into Gun Control receptacle, and tighten threaded collar.
2 Gas Hose
Connect to Gas fitting on feeder.
3Power/Water Cable
4Strain Relief
Remove strain relief as shown.
Route cable through strain relief and connect
to Weld/Water From Gun outlet on feeder
5 Wire Conduit
Route through strain relief. Insert through front panel. Go to Section
6 Water Hose
Connect to Water To Gun fitting on feeder
Air-Cooled Gun:
1 Gun Control Cable
Insert plug into Gun Control receptacle, and tighten threaded collar.
2 Gas Hose
Connect to Gas fitting on feeder.
3 Power Cable
Route cable through front panel and connect to power block. See Section
4 Strain Relief
Remove strain relief as shown.
5 Wire Conduit
Route through strain relief. Insert through front panel. Go to Section