Mitel 3300 manual Specifications, Environment, Condition

Models: 3300

1 78
Download 78 pages 35.43 Kb
Page 16
Image 16
Specifications

General Information Guide - Release 3.1

Specifications

Environment

Storage Environment for 3300 ICP Components and Peripherals

Condition

Temperature

Humidity

Vibration

Mechanical Stress

Specification

3300 Controller: 32º to 104º F (0º to 40º C)

All Other Components: 39º to 120ºF (4º to 49ºC)

15-95% Relative Humidity, non-condensing

0.5g, 5 to 100 Hz, any orthogonal axis

1.5g, 100 to 500 Hz, any orthogonal axis

One 15.3 cm (6 in.) drop, each edge and corner adjacent to the rest face – unpackaged

One 76.2 cm (30 in.) drop, each edge and corner packaged in cardboard & foam.

Operational Environment for 3300 ICP Components and Peripherals

Condition

Specification

Temperature

Humidity

Maximum Heat Dissipation - fully loaded (see Note)

Air Flow

3300 Controller: 59º to 95º F (15º to 35º C)

All Other Components: 39º to 120ºF (4º to 49ºC)

3300 Controller: 40-90% Relative Humidity, non condensing

All Other Components: 34-95% Relative Humidity, non-condensing

724 BTUs per hour

150 cubic feet per minute at maximum output of the fans

Acoustic Emissions

Maximum 50 dBA continuous, 75 dB intermittent (<10% duty cycle)

Conversion factors: 1 watt is equal to 3.412 BTUs per hour, 1 ton of refrigeration is equal to 12,000 BTUs per hour or 3.516 Kilowatts, and 3/4 Kilowatt-hour is equal to 1 ton of refrigeration.