Mitsubishi Electronics 882.00207.00 specifications Feed Algorithm Options Screen

Models: 882.00207.00

1 103
Download 103 pages 37.01 Kb
Page 89
Image 89
Feed Algorithm Options Screen

Typical Advanced Weight Options Screen

Weight Filter

Weight/Sec.

Filter

Feed Algorithm Options Screen

Adjust the limit

for “Hopper Over

Max Weight”

Adjust Settle

Go back to

Engineering Only

Directory

This screen allows the user to configure how the blender metering algorithm works. The user can adjust the Initial percentage of Target to Meter, the Allowed Underfeed value, the number of retries before Double Gate Time, the allowed Weight/Sec Drop, and the Out of Material retry limit.

Typical Feed Algorithm Options Screen

Go back to

Engineering Only

Directory

Feed Calibration Options Screen

This screen allows you to perform the feeder calibrations for each feeder (in weight per second). This is useful when the feed calibration is giving you an error message (most commonly caused by overfilling the hopper during the calibration). Select a feeder and then follow instructions. An error is shown if the current feeder calibration feed time was too short, the feed time was too long, or if the hopper weight exceeded 110% of the set batch weight. In the case that the feeder exceeded

110% (maximum hopper weight) due to a high rate hopper then the “Batch % for Feeder Cal” setting might be set too high. Consult the manufacturer if this problem arises. The current feeder calibration values are also shown on this page. It is not necessary to perform feeder calibrations.

The blender will automatically learn these values during the batch.

Typical Feed Calibration Options Screen

Go back to

Engineering Only

Directory.

882.00207.00

Chapter 7: Appendix

88 of 102

Page 89
Image 89
Mitsubishi Electronics 882.00207.00 specifications Feed Algorithm Options Screen, Feed Calibration Options Screen