Mitsubishi Electronics 882.00207.00 specifications Alarm Log, Alarm Setup

Models: 882.00207.00

1 103
Download 103 pages 37.01 Kb
Page 92
Image 92
Alarm Log

Alarm Setup

This screen allows the user to configure the feeder type for each feeder; configure whether a feeder will retry during the metering of a batch, and enable or disable the “Out of Material” alarm for any feeder. If a hopper is set to “No Retry” then the blender will continue to meter the rest of the batch even if this hopper runs out of material. No “Out of Material” alarm will be given regardless of how the alarm is configured unless the user has purchased and wired in the low level proximity switches in each hopper. To configure each hopper, perform the following steps:

1.Select a feeder by touching the “Select Feeder” box.

2.The current settings for that hopper will be shown.

3.Make the necessary adjustments and select a new feeder to configure if desired.

4. Press “Done” to exit.

Typical Alarm Flags & Feeder Setup Screen

Select a Feeder to

Configure

Change the Alarm

Silence Delay

Enable or Disable Retries

Enable or Disable Alarms

Go back to Setup Directory

Alarm Log

This screen shows the last 100 stored alarms. The log can be viewed, printed and cleared.

Clear Alarm Log

Print Alarm Log

Typical Alarm Log Screen

Alarm Log

Go back to

Setup

Directory

Scroll Through

Alarm Log

882.00207.00

Chapter 7: Appendix

91 of 102

Page 92
Image 92