ADTRAN T3SU 300 1. Near End Alarm Trap Descriptions, Trap Type, If ENABLED, this trap is sent

Models: T3SU 300

1 122
Download 122 pages 32.22 Kb
Page 48
Image 48
Table 3-1. Near End Alarm Trap Descriptions

Chapter 3. Configuration

Table 3-1. Near End Alarm Trap Descriptions

Trap Type

If ENABLED, this trap is sent...

 

 

 

Red Alarm

when the unit detects a loss of signal.

(LOS)

 

 

 

 

Out of Frame

when the unit detects an out of frame condition.

(OOF)

 

 

 

 

Yellow Alarm

when the unit detects an incoming RAI signal.

(RAI)

 

 

 

 

Blue Alarm

when the unit detects an incoming AIS signal.

(AIS)

 

 

 

 

Idle Signal

when the unit detects an incoming idle signal

 

 

(1100) over the entire DS3 bandwidth.

 

 

 

 

Table 3-2. Far End Alarm Trap Descriptions

 

 

 

 

Trap Type

If ENABLED, this trap is sent...

 

 

 

 

Red Alarm

when the unit receives indication from the far

 

(LOS)

end unit through the FEAC channel that the far

 

 

end unit has lost its receive signal.

 

 

 

 

Out of Frame

when the unit receives indication from the far

 

(OOF)

end unit through the FEAC channel that the far

 

 

end unit has lost frame synchronization with the

 

 

network.

 

 

 

 

Yellow Alarm

when the unit receives indication from the far

 

(RAI)

end unit through the FEAC channel that the far

 

 

end unit is receiving an RAI indication from the

 

 

network.

 

 

 

 

Blue Alarm

when the unit receives indication from the far

 

(AIS)

end unit through the FEAC channel that the far

 

 

end unit is receiving an AIS indication from the

 

 

network.

 

 

 

3-16

T3SU 300 User Manual

61200217L1-1

Page 48
Image 48
ADTRAN T3SU 300 user manual 1. Near End Alarm Trap Descriptions, Trap Type, If ENABLED, this trap is sent