![](/images/new-backgrounds/1299584/29958497x1.webp)
|
|
|
| Chapter 3. Configuration |
|
|
|
|
|
|
| Trap Type |
| If ENABLED, this trap is sent... |
|
|
|
|
|
|
| Idle Signal |
| when the unit receives indication from the far |
|
|
|
| end unit through the FEAC channel that the far |
|
|
|
| end unit is receiving an idle signal (1100) over |
|
|
|
| the entire DS3 payload. |
|
|
|
|
|
|
| Eqpt. Fail |
| when the unit receives indication from the net- |
|
| NSA |
| work through the FEAC channel of a |
|
|
|
| |
|
|
|
|
|
|
| Eqpt. Fail SA |
| when the unit receives indication from the net- |
|
|
|
| work through the FEAC channel of a |
|
|
|
| fecting failure in the network equipment. |
|
|
|
|
|
|
| Com. Eqpt. |
| when the unit receives indication from the net- |
|
| Fail NSA |
| work through the FEAC channel of a |
|
|
|
| |
|
|
|
| equipment. |
|
|
|
|
|
|
| Table | ||
|
|
| ||
| Trap Type | If ENABLED, this trap is sent... | ||
|
|
| ||
| Cold Start | when the unit is first powered on. | ||
|
|
| ||
| Link Up | when the network recovers from a Link Down con- | ||
|
|
| dition and data transmission is restored. | |
|
|
| ||
| Link Down | when a network condition prevents data transmis- | ||
|
|
| sion. This could be either an alarm or a network | |
|
|
| test. | |
|
|
| ||
| Auth. Failure | when an SNMP request is made with the wrong | ||
|
|
| read or write community names. | |
|
|
|
| |
|
|
| Table | |
|
|
| ||
| Trap Type | If ENABLED, this trap is sent... | ||
|
|
| ||
| Network Test In | when the unit goes into a DS3 network test, either | ||
|
|
| commanded locally or remotely. | |
|
|
| ||
| Network Test | when the unit is in a DS3 network test and the test | ||
| Out | is terminated. | ||
|
|
|
|
|
T3SU 300 User Manual |