| Chapter 4. Status |
|
|
|
| Condition | Description |
|
|
|
| Blue (AIS) | The unit is receiving a blue alarm condition from |
|
| the network. A blue alarm occurs when consecu- |
|
| tive 1010s are received in the information bits. |
|
| This indicates that there is a transmission fault lo- |
|
| cated either at or upstream from the transmitting |
|
| terminal. |
|
|
|
| OOF | The unit detects an out of frame condition from the |
|
| network. |
|
|
|
| Idle | The unit detects an idle sequence from the net- |
|
| work. Service is immediately available for use. |
|
|
|
Data Link State
This field displays the current state of the data link between the local and the remote T3SU 300s. Possible states are listed in the following table:
Condition | Description |
|
|
Normal | The local unit’s data link is in sync with the remote |
| unit. |
|
|
Disabled | The DATA LINK option in the DS3 NETWORK |
| CONFIGURATION menu is set to DISABLED. |
|
|
Down | The local and remote units are not in sync. |
|
|
Remote State
This field displays the current state of the remote link. Possible states are listed in the following table:
T3SU 300 User Manual |