ADTRAN T3SU 300 Forced On, Follow RS, Ignored, Idle When Off, Off When OOS/OOF, Off When Test

Models: T3SU 300

1 122
Download 122 pages 32.22 Kb
Page 40
Image 40
Forced On

Chapter 3. Configuration

Applying the settings briefly affects all ports of the T3SU 300. You may cancel changes made to the current PORT CONFIGURATION menu by pressing the ESC key.

CS

Selects the control mode for the clear to send (CS) lead. This field only appears if a V.35 interface card is installed in the selected port.

Forced On

The CS lead remains on and request to send (RS) is ignored as long as the unit is synchronized and able to pass data.

Follow RS

The CS state matches the RS state.

TR

Selects the T3SU 300’s response to the data terminal ready (TR) lead. This field only appears if a V.35 interface option card is installed in the selected port.

Ignored

The T3SU 300 ignores the state of the TR lead.

Idle When Off

The T3SU 300 suspends traffic on the selected port if the TR lead is off.

SR

Selects the control mode for the data set ready (SR) lead. This field only appears if a V.35 interface card is installed in the selected port.

Forced On

The SR control lead remains on regardless of the state of the network.

Off When OOS/OOF

The SR control lead remains on unless the T3SU 300 receives an out of service/out of frame (OOS/OOF) condition from the network.

Off When Test

The SR lead remains on except when the T3SU 300 is executing a test.

3-8

T3SU 300 User Manual

61200217L1-1

Page 40
Image 40
ADTRAN T3SU 300 user manual Forced On, Follow RS, Ignored, Idle When Off, Off When OOS/OOF, Off When Test