Performance Parameters

View performance parameter information in one of the three time period selections. Information in these fields is for the given time period since the last reset. When viewing the 24-hour history statistics screen, use the left and right arrow keys to scroll through all 96 15-minute intervals. See Figure 5-4through Figure 5-6for examples of the performance parameter screens.

Descriptions of each field of these screens follow:

Interval starting at:

Time that the 15-minute interval began. This field is only displayed in the 24-hour history screen which gives information for the previous 24 hours divided into 15-minute intervals (shown in Figure 5-3).

Unavailable Seconds (UAS)

Time in seconds that the network port is unavailable for data delivery. This means that the T3 link is down or in test, or that the signaling state is down.

Severely Errored Framing Seconds (SEFS)

Number of seconds with one or more out of frame defects or a detected incoming AIS.

Line Coding Violations (LCV)

Number of BPVs (bipolar violations) and EXZs (excessive zeros) that have occurred.

Line Errored Seconds (LES)

Number of seconds in which one or more CVs or one or more LOS (loss of signal) defects occurred.