Mitsubishi Electronics 882.00273.00 specifications Typical “Maximum Hopper Weight” Alarm Screen

Models: 882.00273.00

1 101
Download 101 pages 4.53 Kb
Page 57
Image 57
Figure 42: Typical “Maximum Hopper Weight” Alarm Screen

Max Hopper Weight Exceeded, check batch size: This alarm indicates that the weight in the weigh hopper has exceeded the maximum allowed weight. This alarm can happen if the operator changes material density and does not perform a feeder calibration, but will usually be automatically fixed after the first batch. As long as this alarm doesn’t continue to reappear, then the operator should not be concerned. If the alarm continues to occur, then the operator should have maintenance check the blender.

Figure 42: Typical “Maximum Hopper Weight” Alarm Screen

MAX HOPPER WEIGHT

EXCEEDED

check batch size

Calibration Error, Clean out hopper and check calibration: This alarm indicates that the maximum empty weight for the weigh hopper has been exceeded. The blender will automatically tare up to 0.25 lbs of material, but if this weight is exceeded, then an alarm will appear. This alarm is most commonly caused by a build up of sticky material in the weigh hopper and can be corrected by simply cleaning out the weigh hopper. If this does not correct the problem, then the scale calibration should be checked by maintenance.

Figure 43: Typical “Calibration Error” Alarm Screen

CALIBRATION

ERROR

Power Interruption while metering a Batch: This alarm indicates that the blender’s power was turned off while the blender was making a batch. The batch accuracy is not affected as long as the blender is configured for “AutoStart.” The blender will finish the last batch accurately even if the material was dumped into the mixer when the power was turned off.

Figure 44: Typical “Power Interruption” Alarm Screen

POWER INTERRUPTION

While metering a

Batch

BF1-615.3