Factory Default Setup Parameters

Factory Default Setup Parameters

 

Model Number

 

150

500

 

900

 

2500

4000

 

6000

 

 

ALL WEIGHT VALUES RECORDED IN POUNDS

 

 

 

 

 

 

(DIVIDE BY 2.20462 FOR KILOGRAMS)

 

 

 

 

 

 

RECIPE FORMAT

 

 

 

 

 

 

 

 

 

 

 

 

Recipe Entry Mode

 

PERCENTAGE

 

"EZ" MODE / "QUICK SET" MODE

 

 

 

Metering Order

 

 

 

12345678

 

 

 

 

 

 

Batch Size (lbs)

 

2.0

4.0

 

8.0

 

25.0

35.0

 

45.0

 

 

Inventory Shutdown

 

 

 

 

0

 

 

 

 

 

 

 

Batch Ready Mode

 

 

 

 

ENABLED

 

 

 

 

 

 

AutoStart Mode

 

 

 

 

ENABLED

 

 

 

 

 

 

Weighing mode

 

 

 

EVERY BATCH

 

 

 

 

 

REPORT SETUP

 

 

 

 

 

 

 

 

 

 

 

 

Blender Number

 

 

 

1

 

 

 

 

 

 

 

Auto Print Inventory

 

 

 

 

DISABLED

 

 

 

 

 

Auto Clear Inventory

 

 

 

 

DISABLED

 

 

 

 

 

Auto Print/Clear Interval

 

 

 

8

 

 

 

 

 

 

 

Start Hour

 

 

 

0

 

 

 

 

 

 

 

SCALE CALIBRATION

 

 

 

 

 

 

 

 

 

 

 

 

PERFORM A SCALE CALIBRATION ON ALL MANUFACTURED UNITS

 

 

 

 

 

DIRECT SCALE READOUT

 

 

 

 

 

 

 

 

 

 

 

 

LOG THESE VALUES AFTER THE SCALE CALIBRATION WITH THE ORDER INFORMATION

 

 

 

FEEDER CALIBRATION

 

 

 

 

 

 

 

 

 

 

 

 

Hop1 wt/sec (lbs)

 

0.25

1.00

 

1.50

10.00

 

 

 

Hop2 wt/sec (lbs)

 

 

0.25

 

 

 

 

3.00

 

 

 

Hop3 wt/sec (with square gate) (lbs)

 

0.25

2.00

 

1.50

10.00

 

 

 

Hop4 wt/sec (lbs)

 

 

0.25

 

 

 

 

3.00

 

 

 

Hop5 wt/sec (lbs)

 

 

0.25

 

 

 

 

3.00

 

 

 

Hop6 wt/sec (lbs)

 

 

0.25

 

 

 

 

3.00

 

 

 

Hop7 wt/sec (lbs)

 

 

0.25

 

 

 

 

1.00

 

 

 

Hop8 wt/sec (lbs)

 

 

0.25

 

 

 

 

1.00

 

 

 

"Feeder Calibration wt/sec" values assume stroke limiters installed

 

 

 

 

 

 

in hoppers #2 & #4 & #5 thru #8

 

 

 

 

 

 

 

 

 

MIXER AND DUMP SETUP

 

 

 

 

 

 

 

 

 

 

 

 

Mixing Time

 

 

 

4

 

 

 

 

 

 

 

Remix Time

 

 

 

0

 

 

 

 

 

 

 

Dump Time

 

1

 

2

 

 

4

 

 

 

 

Dump Delay

 

 

 

0

 

 

 

 

 

 

 

Dump Cycles

 

1

 

2

 

 

1

 

 

 

 

Mixer Dump Time (w/o knifegate set to 0)

 

 

4

 

 

 

 

6

 

 

 

 

Continuous/Timed Mixing

 

 

 

 

TIMED

 

 

 

 

 

 

 

USER PASSWORD

 

 

 

 

 

 

 

 

 

 

 

 

User Password

 

 

 

5413

 

 

 

 

 

 

Maintenance Password

 

 

 

3145348

 

 

 

 

 

 

ALARM SETUP

 

 

 

 

 

 

 

 

 

 

 

 

Hop1 Continue/Stop on Out of Material

 

 

 

 

STOP

 

 

 

 

 

 

Hop2 Continue/Stop on Out of Material

 

 

 

 

STOP

 

 

 

 

 

 

Hop3 Continue/Stop on Out of Material

 

 

 

 

STOP

 

 

 

 

 

 

Hop4 Continue/Stop on Out of Material

 

 

 

 

STOP

 

 

 

 

 

 

Hop5 Continue/Stop on Out of Material

 

 

 

 

STOP

 

 

 

 

 

 

Hop6 Continue/Stop on Out of Material

 

 

 

 

STOP

 

 

 

 

 

 

Hop7 Continue/Stop on Out of Material

 

 

 

 

STOP

 

 

 

 

 

 

Hop8 Continue/Stop on Out of Material

 

 

 

 

STOP

 

 

 

 

 

 

Hop1 Alarm/No Alarm on Out of Material

 

 

 

 

ALARM

 

 

 

 

 

 

Hop2 Alarm/No Alarm on Out of Material

 

 

 

 

ALARM

 

 

 

 

 

 

Hop3 Alarm/No Alarm on Out of Material

 

 

 

 

ALARM

 

 

 

 

 

 

Hop4 Alarm/No Alarm on Out of Material

 

 

 

 

ALARM

 

 

 

 

 

 

Hop5 Alarm/No Alarm on Out of Material

 

 

 

 

ALARM

 

 

 

 

 

 

Hop6 Alarm/No Alarm on Out of Material

 

 

 

 

ALARM

 

 

 

 

 

 

Hop7 Alarm/No Alarm on Out of Material

 

 

 

 

ALARM

 

 

 

 

 

 

Hop8 Alarm/No Alarm on Out of Material

 

 

 

 

ALARM

 

 

 

 

 

 

NETWORK SETUP

 

 

 

 

 

 

 

 

 

 

 

 

Ethernet Configurator

 

 

 

 

ENABLED

 

 

 

 

 

IP Address

 

 

 

192.168.0.10

 

 

 

 

 

Subnet Mask

 

 

 

255.255.255.0

 

 

 

 

 

ADVANCED WEIGHT OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

Weight Filter

 

 

 

5

 

 

 

 

 

 

 

Max Tare Offset (lbs)

 

 

 

1

 

 

 

 

 

 

 

Wt/Sec Filter

 

 

 

1

 

 

 

 

 

 

 

% Above batch size for max weight

 

 

 

25

 

 

 

 

 

 

 

Time to settle hopper after batch dumped

 

 

 

5

 

 

 

 

 

 

 

Simulator

 

 

 

 

Simulator off

 

 

 

 

 

Weight Data Printing

 

 

Don't Print Weight Data

 

 

 

 

BF1-615.3

Chapter 7: 6BAppendix

 

 

 

 

 

92 of 101

Page 92
Image 92
Mitsubishi Electronics 882.00273.00 specifications Factory Default Setup Parameters, BF1-615.3, 6BAppendix, 92 of