13 - 12
13. OPTIONS AND AUXILIARY EQUIPMENT
(b) Resistor unit (FR-BR)[Unit : mm(in)]
33 (1.299)
204
(8.031)
40 (1.575)
K
(F)
(F)
BA 1 (0.039)
C 5
(0.197)
2- D
AA 5 (0.197)
EE
(E)
A 5 (0.197)
EE
(E)
(Note)
Control circuit
terminals
Main circuit
terminals FR-BR-55K
Two eye bolts are provided
(as shown below).
Eye bolt
BB 3 (0.118)
B 5 (0.197)
Note. Ventilation ports are provided in both side faces and top face. The bottom face is open.
Resistor
Unit
Model
AAABBABBCD EEEK F
Approx.
Mass
[kg(Ib)]
FR-BR-
15K 170
(6.693) 100
(3.937) 450
(17.717) 432
(17.008) 410
(16.142) 220
(8.661) 6
(0.236) 35
(1.378) 6
(0.236) 1.6
(0.063) 20
(0.787) 15
(66.139)
FR-BR-
30K 340
(11.389) 270
(10.63) 600
(23.622) 582
(22.913) 560
(22.047) 220
(8.661) 10
(0.394) 35
(1.378) 10
(0.394) 2
(0.079) 20
(0.787) 30
(33.069)
FR-BR-
55K 480
(18.898) 410
(16.142) 700
(27.559) 670
(26.378) 620
(24.409) 450
(17.717) 12
(0.472) 35
(1.378) 12
(0.472) 3.2
(0.126) 40
(1.575) 70
(154.323)
13.1.3 Power regeneration converterWhen using the power regeneration converter, set "01 " in parameter No.0.(1) SelectionThe converters can continuously return 75% of the nominal regenerative power. They are applied tothe servo amplifiers of the MR-J2S-500A to MR-J2S-22KA.

Power

regeneration

converter

Nominal

Regenerative

Power (kW)

Servo Amplifier

FR-RC-15 15 MR-J2S-500A

MR-J2S-700A

FR-RC-30 30 MR-J2S-11KA

MR-J2S-15KA

FR-RC-55K 55 MR-J2S-22KA

05075100150
500
300
200
100
50
30
20
Continuous energization time [sec]