13 - 13
13. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
Power supply
3-phase
200V or 230VAC
NFB MC
Servo amplifier
L11
L21
L1
L2
L3
SK
ON
MC
BC
RDY
SE
Alarm
output
RDY
output
A
B
C
Operation ready
MC
OFF
EMG
RA2
FR-RC
Ready
(Note3)Power factor improving reactor
FR-BAL
R/L1
S/L2
T/L3
B
C
EMG
SON
SG COM
ALM
VDD
RA2
RRX
R
SX
S
TX
T
Phase detection
terminals
(Note 1)
Power regeneration
converter FR-RC
Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed,
the FR-RC will not operate.
2. For the servo amplifiers of 5k and 7kW, always remove the wiring (across P-C) o f the built-in regenerative brake resistor.
3. Refer to the power return converter FR-RC instruction manual (IB(NA)-66330) for the power fa ctor improving reactor to be used.
When using FR-RC with the servo amplifier of 11k to 22kW, do not use the power fact or improving reactor (FR-BEL) together.
4. For the amplifiers of 11k to 22kW, always connect across P-P1. (Wiring is factory-connected.)
NP 5m(16.4ft) or less
N/ P/
(Note2)
CP1
(Note4)