15 - 19
15. ABSOLUTE POSITION DETECTION SYSTEM
15.7.4 Use of servo motor with electromagnetic brakeThe timing charts at power on/off and servo-on (SON) on/off are given below.Preset " 1 " in parameter No. 1 to make the electromagnetic brake interlock (MBR) usable. When theABS transfer mode is ON, the electromagnetic brake interlock (MBR) is used as the ABS data bit 1.Hence, make up an external sequence which will cause the electromagnetic brake torque to be generatedby the ABS mode (ABSM) and electromagnetic brake interlock (MBR).
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
80 [ms]
20 [ms]
Tb
80 [ms]
20 [ms]
Tb
Power
supply
Servo-on
(SON)
ABS transfer mode
(ABSM)
ABS request
(ABSR)
ABS transmission
data ready
(ABST)
Send (ABS) data
Base circuit
Ready
(RD)
Electromagnetic
brake interlock
(MBR)
Electromagnetic
brake torque
During transmission
of ABS
During transmission
of ABS
ABS data ABS data