15 - 14
15. ABSOLUTE POSITION DETECTION SYSTEM
(3) At the time of alarm resetIf an alarm occurs, turn OFF the servo-on (SON) by detecting the alarm output (ALM).If an alarm has occurred, the ABS transfer mo de (ABSM) cannot be accepted.In the reset state, the ABS transf er mode (ABSM) can be input.
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
80[ms]
OFF
ON
OFF
ON
Servo-on
(SON)
Reset
(RES)
ABS transfer mode
(ABSM)
ABS request
(ABSR)
Send data ready
(TLC)
Transmission
(ABS) data
Base circuit
Alarm output
(ALM)
Ready
(RD)
Occurrence of alarm
During transfer of ABS
ABS data
Operation
enabled
OFF
ON