3 - 42
3. SIGNALS AND WIRING
(b) Lamp loadFor use of internal power supply For use of external power supply
24VDC VDD
COM
R
Servo amplifier
ALM, etc.
SG
COM
SG
R24VDC
10%
Servo amplifier
ALM, etc.
VDD
24VDC
Do not connect
VDD-COM.
(3) Pulse train input interface DI-2Provide a pulse train signal in the open collector or differential line driver system.(a) Open collector system1) InterfaceFor use of internal power supply For use of external power supply
VDD
OPC
PP, NP
SG
SD
Servo amplifier
Max. input pulse
frequency 200kpps
About 1.2k
24VDC
2m (78.74in) or less OPC
PP, NP
SG
SD
24VDC
Servo amplifier
Max. input pulse
frequency 200kpps
About 1.2k
VDD 24VDC
Do not connect
VDD-OPC.
2m (78.74in) or less
2) Conditions of the input pulse
0.9
0.1
tc tHL
tc tLH tF
tLH tHL 0.2 s
tc 2 s
tF 3 s
PP
NP