W h e n t h e S T A T U S i n d i c a t o r l i g h t s o r f l a s h e s
STATUS indicator
POWER STATUS
POWER SOURCE AUTO
Status Light Messages
Condition | Status | |
|
| |
OFF | Normal | |
|
| |
On Continually | The lamp usage has exceeded 1000 hours of operation and should be replaced. | |
|
|
|
Flashing Very Rapidly (On and off | • | The lamp cover is not correctly attached. Replace it correctly. |
in a cycle of 1 sec.) |
|
|
|
|
|
Flashing Rapidly | • | The temperature protector has been triggered. If the room temperature is high, |
| move the unit to a cool location. If the temperature within the unit is high, check the | |
(On and off in a cycle of 4 sec.) |
| |
| cooling fan ventilation slots and the ventilation slots on the bottom of the unit. If | |
|
| |
|
| any of the slots are blocked, remove whatever is blocking them. |
| • | The temperature protector has been triggered. If you try to turn on the unit immedi- |
|
| ately after turning off, sometimes the power does not come on. If this happens, wait |
|
| at least one minute, then turn on the unit again. |
| • | The lamp lighting voltage error detection protector has been triggered. Wait at |
|
| least one minute before turning on the unit again. If this does not solve the problem, |
|
| please contact your dealer. |
|
| |
Flashing Slowly (On and off in a | The cooling fan has stopped. Contact your MITSUBISHI dealer for service. | |
cycle of 8 sec.) |
|
|
|
| |
Flashing Very Slowly (On and off in | The lamp is not turned on. | |
a cycle of 12 sec.) | • The unit was turned on immediately after being turned off. Turn off the unit, wait at | |
|
| least one minute, then turn on the unit again. |
| • | The lamp is dead. Replace the lamp cartridge. (See page 33.) |
|
|
|
E – 32