W h e n t h e S T A T U S i n d i c a t o r l i g h t s o r f l a s h e s

STATUS indicator

POWER STATUS

POWER SOURCE AUTO

Status Light Messages

Condition

Status

 

 

OFF

Normal

 

 

On Continually

The lamp usage has exceeded 1000 hours of operation and should be replaced.

 

 

 

Flashing Very Rapidly (On and off

The lamp cover is not correctly attached. Replace it correctly.

in a cycle of 1 sec.)

 

 

 

 

 

Flashing Rapidly

The temperature protector has been triggered. If the room temperature is high,

 

move the unit to a cool location. If the temperature within the unit is high, check the

(On and off in a cycle of 4 sec.)

 

 

cooling fan ventilation slots and the ventilation slots on the bottom of the unit. If

 

 

 

 

any of the slots are blocked, remove whatever is blocking them.

 

The temperature protector has been triggered. If you try to turn on the unit immedi-

 

 

ately after turning off, sometimes the power does not come on. If this happens, wait

 

 

at least one minute, then turn on the unit again.

 

The lamp lighting voltage error detection protector has been triggered. Wait at

 

 

least one minute before turning on the unit again. If this does not solve the problem,

 

 

please contact your dealer.

 

 

Flashing Slowly (On and off in a

The cooling fan has stopped. Contact your MITSUBISHI dealer for service.

cycle of 8 sec.)

 

 

 

 

Flashing Very Slowly (On and off in

The lamp is not turned on.

a cycle of 12 sec.)

• The unit was turned on immediately after being turned off. Turn off the unit, wait at

 

 

least one minute, then turn on the unit again.

 

The lamp is dead. Replace the lamp cartridge. (See page 33.)

 

 

 