4.4.4.Memory tab

Registered memories can be called or deleted in the memory tab.

1.Select panels to call the memory.

2.Input a memory number to be called in “Memory No.” and click “Call” button.

Or you can also call it by double-clicking the memory number in the list box.

To delete a memory, select the memory in the list box and check “Delete” in the right-click menu.

With remote control

 

Wallaby menu

Page

INPUT MEMORY

Input Memory

 

56, 65

DISPLAY MEMORY

Display Memory

 

68

“Memory List” button can update the memory list.

“Automatically read parameters” can automatically update the selected memory data in the software for synchronization with the cubes whenever you call the memory. Even if unchecked, you can update it later according to the “Data reading” on page 101.

4.4.5.Information tab

It displays current status information of a selected cube.

“Timer Reset” button has the same function as “Reset” button in “Maintenance” in Service tab (on page 102).

“Filter” menu appears only in Front or when DIRECTION menu is set FRONT. The filter used hours (on page 84) can be reset by the “Filter Reset” button.