VENTING INSTALLATION

VENTING INSTALLATION

Designer Series Gas Fireplaces

VentING installation

 

Read all instructions completely and

WARNING

thoroughly before attempting installation.

Failure to do so could result in serious

 

 

injury, property damage or loss of life.

 

Operation of improperly installed and

 

maintained venting system could result in

 

serious injury, property damage or loss of

 

life.

 

 

 

 

NOTICE

Failure to follow these instructions

 

 

will void the warranty.

 

 

VENTING CLEARANCES

 

Horizontal sections of this vent system

 

require a minimum of 3" clearances to

WARNING

combustibles at the top of the flue and 1"

clearance at the sides and bottom until

 

 

the flue penetrates the outside wall. A

 

minimum 1" clearance all around the flue

 

is acceptable at this point of penetration.

 

Vertical sections of this vent system require

 

a minimum of 1" clearance to combustibles

 

on all sides of the pipe.

 

 

Installation precautions

NOTE: This appliance must be installed with a Monessen approved venting system only.

Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.

Only a qualified installer/service person should install vent- ing system. The installer must follow these safety rules:

Wear gloves and safety glasses for protection.

Use extreme caution when using ladders or when on rooftops.

Be aware of electrical wiring locations in walls and ceilings.

The following actions will void the warranty on your vent- ing system:

Installation of any damaged venting component.

Unauthorized modification of the venting system.

Installation of any component part not manufactured or approved by MHSC.

Installation other than permitted by these instruc- tions.

*3"VentING installationRead all instructions completely and

thoroughly before attempting installation. **1” 326M

**1"

FP2280

*A minimum of 3" clearance to the top is required along horizontal length until flue pipe penetrates outside wall.

**A minimum 1" clearance to combustibles permitted all around flue at outside wall.

Figure 12 -

Combustible Clearances for Vent Pipe

WARNING

This fireplace must be vented to the

outside. The venting system must NEVER

 

 

be attached to a chimney serving a separate

 

solid fuel burning appliance. Each gas

 

appliance must use a separate vent system.

 

Do not use common vent systems.

 

 

42D0200

13