Monessen Hearth CR General troubleshooting, Glass replacement and blower, Symptom, Possible Cause

Models: CL)NVC/PVC PF 624DV(ST CR

1 52
Download 52 pages 60.61 Kb
Page 41
Image 41
Designer Series Gas Fireplaces

troubleshooting

Designer Series Gas Fireplaces

General troubleshooting

 

SYMPTOM

POSSIBLE CAUSE

ACTION

6. Glass Soots

A. Flame impingement

 

on logs

A. Install log set per the instructions

Inspect the injector and air intake area. Make sure this area does not have any blockage from debris and clean.

Check gas supply.

7. Flame burn blue

A. Insufficient oxygen

and lifts off burner

being supplied

(ghosting)

 

A.Ensure that the vent cap is installed properly and free of debris. Ensure that the vent system joints are tight and have no leaks. Ensure that no debris has been blocking the inner air intake at the bottom back of the combustion chamber. Ensure that the glass is properly secure and latch.

WARNING

Make sure the glass panel edges do not touch any metal parts during thermal expansion.

CAUTION

Glass replacement and blower

Always use gloves when handling broken glass.

Never operate fireplace if glass is broken.

Replace any glass that is chipped, cracked, or broken. Replacement glass assemblies MUST be supplied by fireplace manufacturer — No substitute materials may be used.

optional Blower accessory - BLOT

wiring diagram for Blower

Attach Blower to T-Stat

Green Green

120 VAC

White

Blower

 

Black

Blower Plug

120 VAC

Black Black

 

Speed Control

 

ON/OFF Wall Switch or

Optional Variable Speed Switch

120 VAC

60Hz

Factory Supplied

Not Supplied

Junction Box

42D0200

41

Page 41
Image 41