Optional top vent application
The appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent configuration the appli- ance can be converted by following the steps below.
When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required.
1.Remove the eight (8) screws securing the flue pipe adapter to the fireplace body. Figure 9
WARNING
After conversion to top vent configuration the 4" (102 mm) flue pipe should be concentric within the 6B\," (175 mm) outer collar (within 1/4").
2.Set the flue pipe adapter aside, complete with the gasket. Do not damage the gaskets as the adapter and gasket must be refitted.
3.Remove the eight (8) screws securing the flue pipe cover to the top of the intake box and remove the cover and gasket. Figure 9
4.Remove eight (8) screws securing the flue pipe to the back of the intake box and remove the pipe and gasket. Figure 10
5.Replace flue pipe to top of firebox. Ensure the gasket is in place and undamaged. Secure with eight (8) screws. Figure 11
6.Place the flue pipe cover and gasket removed in step 3 over the flue opening in bottom of the intake box.
7.Refit the flue pipe adapter and gasket to the top of fire- place. Secure the adapter with eight (8) screws removed in step 1.
Flue Pipe
Adapter
Flue Pipe
Adapter
Screws
FP1991
| Figure 9 | - |
Flue Pipe | Remove | 16 Screws from Flue Pipe |
Cover | Adapter and Flue Pipe Cover |
Screws
Flue Pipe
Screws
Flue Pipe
Figure 10 - Remove Flue Pipe
FP1992
Figure 11 -
Attach Flue Pipe to Top Vent Coln- figuration