clearances

Designer Series Gas Fireplaces

Clearances to combustibles

 

Follow these instructions carefully to ensure safe installation. Failure

WARNING

to follow instructions exactly can create a fire hazard.

or noncombustible material panel extending full width and depth of

 

The appliance cannot be installed on a carpet, tile or other

 

combustible material other than wood flooring. If installed on carpet

 

or vinyl flooring, the appliance shall be installed on a metal, wood

 

the appliance.

 

 

mantel clearances

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.

10”

 

 

 

8”

 

12”

6”

 

 

4”

 

10”

 

 

 

8”

2”

 

 

6”

 

 

4”

Wall

Insulation Board

Standoff

Top of Louvers

Figure 6 -

Mantel Clearances

FP2279

WARNING

Never obstruct or modify the air inlet or outlet grills (louvers). This may create a fire hazard.

Finishing Material

NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction.

Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to cover the black-painted face of the appliance. A 300°F minimum adhesive may be used to attach facing materials to the black surface. If joints between the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or equivalent) must be used. Combustibles may come to the top and side edges but not overlay the face.

42D0200

Page 9
Image 9
Monessen Hearth CR, PF, CL)NVC/PVC, 624DV(ST manual Clearances to combustibles, Mantel clearances, Finishing Material