15
Input Field Default: Port 1
The Input field displays the input to which the decoder is currently tuned. It allows
manual selection of Port 1 through Port 8 or the ASI input so that the DSR-6000
can acquire the DigiCipher II system signal and automatically download network
data required for operation. To select the input:
Press the4button until the cursor is at the Input label and press the ENTER button.
Press the 56 buttons to scroll to the input that is connected. Unless changed, the
DSR-6000 displays values for Port 1. Press ENTER to confirm the selection and
return to the top line of the menu. If Port 1 through Port 8 is selected, then move to
the Mode field, Xpndr field, or Lfreq field. These three fields are not visible when
ASI In is selected.
The following screen prompts the user to confirm the selection.
If you press any arrow button (3456) at this point, the Caution screen
disappears and the MANUAL TUNE menu reappears without any changes. To set
the port selection, press the ENTER button.
Mode Field Default: Xpndr
The Mode field allows selection of the frequency plan type for the satellite signal to
which the DSR-6000 is tuned. If the application is a North American C-band
satellite center frequency, select the transponder number in the Xpndr field.
Otherwise, use the L Freq option and the LFreq field. The L Freq option can be
used for current satellite LNB signals, including C-band and Ku-band.
Press the4button until the cursor is on the Mode label. Then press the ENTER
button to move into the field. There are two choices: Xpndr and L Freq. Press the
56 buttons to display the desired choice. Then press the ENTER button to
confirm the selection.
If Xpndr is selected, choose a transponder in the Xpndr field. The frequency in the
LFreq field is set automatically and cannot be edited.
If L Freq is selected, the Xpndr field no longer appears because the transponder/
frequency relationship is not known. Select a transponder frequency between 950
and 2150 MHz in the LFreq field. This field is not available when the ASI In option
in the Input field is selected.
Press E to continue or to stop
CAUTION: Service will be interrupted