23
Alarm Menu
Press the6 button until the ALARM menu is located. This menu allows the user to set
up different trigger options for the DSR-6000 to go into an alarm condition This option
illuminates the front-panel Alarm LED and energizes the back-panel alarm relay.
Trigger Field Default: AUTO
Press the4button until the cursor is at the Trigger label, and press the ENTER button
to move into the field. Press the 56 buttons to display the options. The Trigger field
allows the user to select the trigger condition for which the alarm is activated. When
the alarm is activated, the Alarm LED illuminates and the alarm relay indicates an
alarm condition. With the AUTO (default) trigger setting, the alarm is activated for
any of the following conditions:
The tuner looses lock when the input is RF (Loss of the Signal LED).
The DSR-6000 cannot lock to the ASI input when the specified input is ASI.
The DSR-6000 is unable to render video.
The DSR-6000 is not authorized to access the selected service.
There are six options: Auto, No Signal, No Video, No Auth (Authorization),
AUTO+HDD, and Disabled. Use this option to select which of the above
conditions activates the alarm.
Test Field Default: Off
The Test field provides an alarm test. The alarm is activated when this field is set to
On. The Test field returns to the default value (Off) when the field is exited.
E Auto Off
ALARM Trigger Test