47
Menus Field Default: Off
The Menus field allows the user to enable or disable the on-screen diagnostics.
Press the4button until the cursor is at the Menus label, and press the ENTER
button to move into the field. Press the 56 buttons to scroll to the televised screen
of choice. Press the ENTER button to exit this field.
Notice that if the Menus field is ON, the Clear_Cntrs (clear counters) field also appears.
Clear_Cntrs Field
This field allows the user to reset selected counters to zero. This field is primarily for
use with hotline troubleshooting, and it is recommended that it be used only when so
directed and does not affect decoder operation, but it may give misleading
troubleshooting results. To clear counters, press the4button until the cursor is at the
Clear_Cntrs label, and press the ENTER button to reset the counters to zero.
KS Field
Use this field to set the Key Stream (and associated service) which applies to
Diagnostics B.
Unit Address Menu
This menu is for display only and displays the DSR-6000’s 16-digit electronic
address (range: 000-00000-00000-000 to 999-99999-99999-999). The program
provider uses this address to identify a specific DSR-6000 for authorization and to
retune messages. The display enables the user to view the address from the front
panel rather than reading the label on the back panel.
Press the 56 buttons until the Unit Address menu appears.
E On 0 No
DIAG Menus KS Clear_Cntrs
E ddd-ddddd-ddddd-ddd
UNIT ADDRESS Address