![](/images/new-backgrounds/1052565/5256541x1.webp)
4. INSTALLATION
4-11. Connecting the cords
CAUTION
Be sure to connect the ground. If the ground connection is not secure, you run a high risk of receiving a serious electric shock, and problems with correct operation may also occur.
NOTE:
The harness is connected in the same way regardless of whether the machine head is positioned horizontally or vertically.
4-11-1. Connecting the ground wire
(5) | (3) |
|
| Grounding | |
|
| mark (2) |
| (8) |
|
(4) |
| (7) |
|
| |
| (2) (6) | Grounding |
(1) | mark |
2061Q
1.Remove the 12 screws (1), and then open the covers (2) on both sides of the control box.
NOTE:
When opening the covers (2), hold them securely so that they do not fall down.
2.Insert the panel harness(3) into the control box.
3.Connect the ground wire (4) which is protruding out from the hole in the control box to the leg (5). Connect the ground wire (6) coming from the machine head to the ground wire (7) inside the control box. Connect the ground wire in the middle of the panel harness to the ground wire (8) inside the control box. (Grounding marks are displayed on the machine head and inside the control box.)
*If the shape of the grounding screw in the leg (5) requires a different ground wire to be connected,
NOTE:
If the ground wires are not connected, incorrect operation may result.
If the grounding point has been painted over, remove the paint coating before connecting the ground wire.
4-11-2. Connecting the machine head harness
(1)
1.Insert the machine head harness (1) into the control box.
2.Tilt back the machine head.
3.Pull the harness (1) through the cord clamp (2) at the top of the control box. This cord clamp is not used when the machine head is positioned horizontally.
(2)
2062Q
14 |
|