![](/images/new-backgrounds/1052565/5256551x1.webp)
2075Q
Work table hole positions
(2)
(4)
|
| (1) |
|
| 2076Q |
| (3) |
|
| (5) |
|
| (6) |
|
| (7) |
|
| (3) | 2 mm |
|
| |
| (5) |
|
| (6) |
|
2077Q | (7) | 2078Q |
|
4. INSTALLATION
4) Installation underneath the work table
*Standard BROTHER work tables are provided with installation holes for use in installing the transformer.
1.Remove the screws (1), and then remove the handle (2).
2.Use the bolts (4), flat washers (5), spring washers
(6)and nuts (7) to install the transformer as shown in the illustration, while leaving a gap of 2 mm between the work table and the cushion collars (3).
Use the bolts (4), flat washers (5), spring washers (6), nuts (7) and cushion brackets (3) which are included.
<Connecting the cords>
2079Q
(3)
(2)
(6)
(4)(5)
(1)
(6)
(5)(1)
2080Q
1.Loosen the screws (1), and then remove the transformer cover (2).
2.Connect the control box connector (3) to the transformer connector (4).
3.Secure the connected cords with the cord holder
(5) and the screw (6), and place them inside the transformer cover (2). Install the transformer cover (2) with the screws (1).
4.Secure the cords to the work table using staples.
19 |