Software Configuration B - 7
Ignition TimeoutKey Name: [HKEY_CURRENT_USER\ControlPanel\SystemManagement\UPS]
•
Name: Ignition Timeout
•Data Type: dword
•Description: Forklift ignition timeout
•Default Value: 00000180: 3 minutes.
•Options:
• 00000000: Never.
• 00000060: 1 minute.
• 00000120: 2 minutes.
• 00000180: 3 minutes.
• 00000300: 5 minutes.
• 00000600: 10 minutes.
• 00000900: 15 minutes.
• 00001800: 30 minutes.
Registry Values for P1/P2/P3 KeysKey Name: [HKEY_LOCAL_MACHINE\SOFTWARE\symbol\ProgrammableKeys\P1]
[HKEY_LOCAL_MACHINE\SOFTWARE\symbol\ProgrammableKeys\P2]
[HKEY_LOCAL_MACHINE\SOFTWARE\symbol\ProgrammableKeys\P3]
•
Name: Action
•Data Type: REG_dword
•Description: Sets the function of the Px key.
•Default Value: 00000000: No action.
•Options:
• 00000000: No action.
• 00000001: Launch Application.
• 00000002: Simulate Key Press.
• 00000003: Toggle SIP.
• 00000004: Toggle Touch.
• 00000005: Toggle Keylight.
• 00000006: Play Key Sequence.
• 00000007: Launch calibration.
•
Name: ApplicationPath
•Data Type: String
•Description: Used to specify which application to invoke with the press of Px key. Required only when
action is Launch Application.
•
Name: CommandLine
•Data Type: String
•Description: Used to specify any command line argument to the application to be invoked with the press
of Px key. Required only when action is Launch Application.