UC-7420/7410 User’s Manual

Managing Embedded Linux

SxxRUNFILE stands for

S: start the run file while linux boots up.

xx:a number between 00-99. The smaller number has a higher priority. RUNFILE: the file name.

192.168.3.127 – PuTTY

root@Moxa:/ect/rc.d/rc3.d# ls

S19nfs-common S25nfs-user-server S99showreadyled

S20snmpd S55ssh

S24pcmcia S99rmnologin

root@Moxa:/ect/rc.d/rc3.d# ln –s /root/tcps2-release S60tcps2

root@Moxa:/ect/rc.d/rc3.d# ls

 

S19nfs-common

S25nfs-user-server S99rmnologin

S20snmpd

S55ssh

S99showreadyled

S24pcmcia

S60tcps2

 

root@Moxa:/etc/rc.d/rc3.d#

KxxRUNFILE stands for

K: start the run file while linux shuts down or halts.

xx:a number between 00-99. The smaller number has a higher priority. RUNFILE: is the file name.

For removing the daemon, you can remove the run file from /etc/rc.d/rc3.d by using the following command:

#rm –f /etc/rc.d/rc3.d/S60tcps2

Adjusting the System Time

Setting the Time Manually

UC-7420/7410 has two time settings. One is the system time, and the other is the RTC (Real Time Clock) time kept by the UC-7420/7410 hardware. Use the #date command to query the current system time or set a new system time. Use #hwclock to query the current RTC time or set a new RTC time.

Use the following command to query the system time:

#date

Use the following command to query the RTC time:

#hwclock

Use the following command to set the system time:

#date MMDDhhmmYYYY

MM= Month

DD = Date

hhmm = hour and minute YYYY = Year

Use the following command to set the RTC time:

#hwclock –w

Write current system time to RTC

The following figure illustrates how to update thesystem time and set the RTC time.

3-9

Page 49
Image 49