Chapter 3 – Related MultiVOIP Setup Parameters

FXO Parameters. The parameters applicable to the FXO telephony interface type are shown in the figure below and described in the table that follows.

 

FXO Interface: Parameter Definitions

Field Name

Values

Description

Interface, FXO

Y/N

Enables FXO functionality

Dialing Options

 

Regeneration

Pulse, DTMF

Determines whether digits generated and sent out will be pulse tones

 

 

or DTMF.

Message

--

Not applicable to FXO interface.

Waiting

 

 

Indication

 

 

Inter Digit

50 to 20,000

The length of time between the outputting of DTMF digits.

Regeneration

milliseconds

Default = 100 ms.

Time

 

 

FXO Disconnect On

There are three possible criteria for disconnection under FXO: current

 

 

loss, tone detection, and silence detection. Disconnection can be

 

 

triggered by more than one of the three criteria.

Current Loss

Y/N

Disconnection to be triggered by loss of current. That is, when

 

 

Current Loss is enabled (“Y”), the MultiVOIP will hang up the call

 

 

when it detects a loss of current initiated by the attached device.

Current Loss

integer values

The minimum time required for detecting the current loss signal on

Detect Timer

(in milliseconds )

the FXO interface. In other words, this is the minimum length of

 

 

time the current must be absent to validate ‘current loss’ as a

 

 

disconnection criterion. Default = 500 ms.

Tone Detection

Y/N

Disconnection to be triggered by a tone sequence.

 

 

 

46

Multi-Tech Systems, Inc. Avaya Communication Manager Guide

Page 46
Image 46
Multi-Tech Systems 410, MVP103 manual FXO Interface Parameter Definitions, Dialing Options