Chapter 3 – Related MultiVOIP Setup Parameters
FXS Loop Start Parameters. The parameters applicable to FXS Loop Start are shown in the figure below and described in the table that follows.
FXS Loop Start Interface: Parameter Definitions
Field Name | Values | Description |
FXS (Loop | Y/N | Enables FXS Loop Start interface type. |
Start) |
|
|
|
|
|
Dialing Options fields |
| |
|
|
|
Inter Digit | 1 - 10 seconds | This is the length of time that the MultiVOIP will wait between |
Timer |
| digits. When the time expires, the MultiVOIP will place the call. |
|
| Default = 2. |
|
|
|
Message | If “Register with Communication is enabled”, this field enables | |
Waiting |
| message waiting indication on FXS channels. Choices are “Light” or |
Indication |
| “Stutter Dial Tone”. |
|
|
|
Inter Digit | in milliseconds | The length of time between the outputting of DTMF digits. |
Regeneration |
| Default = 100 ms. |
|
| |
Time |
|
|
|
|
|
Ring Count, | Maximum number of rings that the MultiVOIP will issue before | |
FXS |
| giving up the attempted call. |
|
|
|
FXS Options, | Y/N | When enabled, the MultiVOIP will interrupt loop current in the FXS |
Current Loss |
| circuit to initiate a disconnection. This tells the device connected to |
|
| the FXS port to hang up. The |
|
| FXS device must go on hook. |
44 |