Chapter 3 – Related MultiVOIP Setup Parameters

FXS Loop Start Parameters. The parameters applicable to FXS Loop Start are shown in the figure below and described in the table that follows.

FXS Loop Start Interface: Parameter Definitions

Field Name

Values

Description

FXS (Loop

Y/N

Enables FXS Loop Start interface type.

Start)

 

 

 

 

 

Dialing Options fields

 

 

 

 

Inter Digit

1 - 10 seconds

This is the length of time that the MultiVOIP will wait between

Timer

 

digits. When the time expires, the MultiVOIP will place the call.

 

 

Default = 2.

 

 

 

Message

--

If “Register with Communication is enabled”, this field enables

Waiting

 

message waiting indication on FXS channels. Choices are “Light” or

Indication

 

“Stutter Dial Tone”.

 

 

 

Inter Digit

in milliseconds

The length of time between the outputting of DTMF digits.

Regeneration

 

Default = 100 ms.

 

 

Time

 

 

 

 

 

Ring Count,

1-99

Maximum number of rings that the MultiVOIP will issue before

FXS

 

giving up the attempted call.

 

 

 

FXS Options,

Y/N

When enabled, the MultiVOIP will interrupt loop current in the FXS

Current Loss

 

circuit to initiate a disconnection. This tells the device connected to

 

 

the FXS port to hang up. The Multi-VOIP cannot drop the call; the

 

 

FXS device must go on hook.

44

Multi-Tech Systems, Inc. Avaya Communication Manager Guide

Page 44
Image 44
Multi-Tech Systems 410, MVP103 manual Fxs