Chapter 4 - S-Registers

S30

Inactivity Timer

 

Unit: 1 minute

 

Range: 0, 1–255 minutes

 

Default: 0 (disabled)

 

S30 can be used to cause the modem to disconnect if no data is transmitted or received for

 

a specified time. S30 runs during both reliable and non-error correction connections. The

 

timer restarts any time a data character passes through the serial port (either sent or

 

received). If noise on the phone line causes an error to be received during non-error

 

correction mode, this also will restart the S30 timer. The factory default of zero disables the

 

timer.

S32

Time Lapse for Escape Sequence

 

Unit: 100 ms

 

Range: 0–255

 

Default: 20 (2 seconds)

 

S32 sets the time period to validate the escape sequence. If the S32 time interval expires

 

before you press ENTER, then the escape sequence is aborted. The default is two seconds.

S34

Command Buffer Length After Online Escape Sequence

 

Unit: Decimal

 

Range: 0–60

 

Default: 10

 

Sets the number of characters allowed in an AT command after an in-band online escape

 

(+++ method). If the number of characters after “AT” exceeds the S34 buffer length value,

 

then the buffer is flushed and the escape sequence is aborted.

S36

DTR Busy-Out Time

 

Unit: 1 second

 

Range: 0–255

 

Default: 0 (disabled)

 

S36 sets the time between when DTR goes inactive and when the modem goes off-hook.

 

The DTR busy-out feature is disabled when S36 is set to 0.

 

Normally, when the DTR signal from the computer goes inactive, the modem goes on-hook

 

after a time that is set by S25. If S36 is set for a non-zero time, the modem then waits for the

 

time set by S36; if DTR has not gone active again in that time, the modem goes off-hook,

 

causing a busy signal for callers. The busy-out state ends when DTR goes active again.

S37

DTR Busy-In Time

 

Unit: 1 second

Range: 0–255

Default: 5

S37 sets the time between when DTR goes active and when the modem goes on-hook, if S36 has caused it to go off-hook.