User Guide
Trademarks
Revision Date Description
Contents
Registers
Warranty & Service
Index 116
Introduction
Manual Organization
Introduction
Description
FCC Regulations for Telephone Line Interconnection
FCC Fax Update
Canadian Limitations Notice
Technical Specifications
Fax Carrier
Diagnostics
Bell 103/113
300 bps
Power Supply
Data Rate bps LED State
Modem LED Indicators
Busy Switch
Speed
Safety Warnings
10 MT2834MR6 Installation Notes
Dialing and Answering
Dial-Up Handshaking Details
Dial-Up Automatic Answering
Call Termination
AT Commands
Modes of Operation
Working with AT Commands
Command Editing
Command Structure
AT Commands
Serial port baud rate
Baud adjust
Flow control disabled
Modem baud rate
Go back online
Force answer mode
Alternate out-of-band escape sequence
Escape sequence selection
= phone number
Dialing Commands
Default none
Dial
Pulse or Tone Dialing
Dial Modifier Commands
Default P
Default R0
Or 4 through 255 seconds International models
ATDT1028806127853500 $123456789
NdNe Number Linking = 0 or = 1 or Default none
Phone Number Memory Commands
P9,T14089876543
T14082345678
= 0, 8, or
Configuration Storage and Recall Commands
Default &W1
Default &F8
AT&F9&W0
AT&W1 default
ATZ
AT&F8&W0
Modem Response Result Code Commands
Result Codes and Call Progress Selection
Default
Default &A0
DCn AT Command Control = 0 or Default %DC0
Online Connection Commands
#An Auto Speed Detection Default #A0
Default B0
#Fn Fallback Modes = 0, 1, or Default #F2
CDn Cleardown at Disconnect = 0 or Default &CD0
DTn Dtmf Detection = 0 or Default DT0
G2 U.K. models only
Default &G0 models outside U.K
Default *H0
Default &P0 Models outside U.K
Issued
#T0 disables TCM
#T1 enables TCM
Default Y0
V.34 Commands
Default &R1
RS-232 Interface Commands
Default &C1
Default &D2
S1 allows DSR to act normally, that is, to follow CD
Default &S1
Go high again
S0 forces DSR high
#Ln Error Correction Modes Default #L0
Error Correction and Data Compression Commands
Default &E1
Default &E15
$Rn Retransmit Count = 0 or Default $R0
$En Error Correction at 300 bps = 0 or Default $E0
$An Autoreliable Buffering = 0 or Default $A0
Speed Conversion Commands
$SB2400
$SBn Serial Port Baud Rate = speed Default $SB57600
$SB300
$SB1200
Immediate Action Commands
Rate Renegotiation
Flow Control Disable
Flow Control Commands
BSn Maximum Reliable Block Size = 0 or Default &BS1
$EBn Asynchronous Word Length = 0 or Default $EB0
Default &E10
Default &E6
Default &E8
Non-Error Correction Mode Flow Control
= 12 or
Default &E13
#Xn Number of Xoff Characters Sent = 0 or Default #X0
Pacing Computer-Initiated Flow Control
Escape Sequences
Atcr Remote Configuration Escape Sequence
Remote Configuration Commands
Line Probe Commands
Diagnostic Commands
Registers
Registers
Return Character
Default 13 M
Default 10 J
Default 8 H
Range 1-255 U.S.A
Time for Carrier Abort Timer
Default 45 North America and International
Unit 1 second
Maximum S11 value is 255 ms 255 units
Registers
Registers
Examples of Reading Values
Reading and Assigning S-Register Values
Examples of Assigning Values
AT Commands Affecting S-Registers
Error Correction, Data Compression & Speed Conversion
Error Correction, Data Compression, and Speed Conversion
How V.42 Detects and Corrects Errors
MNP Classes
Data Compression
3 #L2 Command
V.42 Mode Select Command #L
1 #L0 Command
2 #L1 Command
Modes of Operation
Non-Error Correction Mode &E0
Reliable Mode &E2
Autoreliable Mode &E1
Flow control and pacing
Flow Control
Hardware Flow Control &E4
Modem-Initiated Flow Control
1 XON/XOFF Flow Control &E5
Hewlett Packard ENQ/ACK Pacing &E9
Non-Error Correction Mode Flow Control &E10 and &E11
Pacing &E13
1 XON/XOFF Pass-Through &E7
10.3 XON/XOFF Pass-Through
10.1 V.42 Error Correction Modes
Non-Error Correction Mode Flow Control
Modem-Initiated Flow Control
Speed Conversion
MNP Error Correction
LAP-M Error Correction
Result Codes
Modem Baud Rate $MB
Baud Adjust $BA
Serial Port Baud Rate $SB
Autoreliable Fallback Character $F
Related Commands
Autoreliable Buffering $A
Maximum Block Size &BS
Retransmit Count $R
13.5 V.42 Error Correction at 300 bps $E
Summary
Testing & Troubleshooting
Testing and Troubleshooting
Local Analog Loopback Test V.54 Loop
Test Procedure
Remote digital loopback test
Remote Digital Loopback Test V.54 Loop
Local digital loopback test
Local Digital Loopback Test V.54 Loop
Warranty & Service
2 U.S. and Canadian Customers
Multi-Tech Systems, Inc. Warranty & Repairs Policies
Warranty
International Distributors
International Customers outside U.S.A. and Canada
Repairs
Repair Procedures for U.S. and Canadian Customers
Repair Procedures for International Customers
Country Telephone
Technical Support
Internet Site
Appendices
Appendix a
Ascii Conversion Chart
Dial Pulses
Appendix B
Figure B-2. Standard Dtmf frequencies
Tone Dial Frequencies
Result Code Summary
Appendix C
Standard AT Result Codes &Q1
Register Summary
Register Unit Range Default Description
Appendix D
S34
Appendix E
AT Command Summary
Command Values Description
CDn
100
101
102
103
104
105
Appendix F
RS-232C Interface Specifications
Signal Information Negative Positive
Transmitted Data TD Pin 2 To modem
Functional Description of the RS-232C Signals
Test Voltage +V Pin From modem
External Transmit Clock XTC Pin To modem
Appendix G
Cable and Connector Diagrams
Introduction to MultiTech Escape Methods
Appendix H
Escape Method 1 +++ATCR
How to Select an Escape Method
Aborting an Escape Sequence
Registers and Escape Sequence
Setup
Introduction to Remote Configuration
Basic Procedure
Changing the Remote Escape Character
Changing the Passwords
Index
Index
118
119
120
121
122
S000326A