MT2834ZPX Owner's Manual

COMMAND:

&Cn

VALUES:

n = 0, 1, 2 or 4

DEFAULT:

&C1

DESCRIPTION:

 

 

&C0 forces Carrier Detect on.

 

&C1 lets Carrier Detect act normally.

 

&C2 lets Carrier Detect drop S24 time on disconnect.

 

&C4 resets modem when Carrier Detect drops.

COMMAND:

&CDn

VALUES:

n = 0 or 1

DEFAULT:

&CD0

DESCRIPTION:

 

 

&CD0 execute cleardown on disconnect.

 

&CD1 do not execute cleardown on disconnect.

COMMAND:

Ds

VALUES:

s = phone #

DEFAULT:

n/a

DESCRIPTION:

 

 

Dial a telephone number “s” , where s may

 

include up to 60 digits or T, P, R, comma and ; characters.

COMMAND:

DsNd

VALUES:

s = phone # and d = 0 thru 9

DEFAULT:

n/a

DESCRIPTION:

 

 

Store telephone number. To store, phone number ”s“ is en

 

entered and followed by N and then Directory Number “d.”

COMMAND:

&Dn

VALUES:

n = 0 thru 3

DEFAULT:

&D2

DESCRIPTION:

 

 

&D0 means DTR is ignored

 

&D1means modem returns to command mode.

 

&D2 lets modem react to DTR normally.

 

&D3 causes modem to reset to modem default parameters.

COMMAND:

$Dn

VALUES:

n = 0 or 1

DEFAULT:

$D0

DESCRIPTION:

 

 

$D0 disables DTR Dialing.

 

$D1 enables DTR Dialing.

26

Page 26
Image 26
Multi-Tech Systems MT2834ZPX owner manual Command Values