Chapter 4 - AT Commands,
S13
Remote Configuration Escape Character
Unit: ASCII Character Range:
Description: Defines the remote configuration escape character.
S17
Changing Break Time
Unit: 10 mSec. Range:
Description: S17 defines the break time (space) to local PC.
S24
PBX/CBX Disconnect Drop Time for DSR/CTS/CD
Unit: | 50 mSec. |
Range: | |
Default: | 20 |
Description: Defines DSR/CTS/CD dropout time. The default of 20 equals one second.
S25
DTR Dropout Time
Unit: 100 mSec. Range: 0, 1 through 255 Default: 0
Description: Defines DTR dropout time. 0 default equals 50ms.
S26
Failed Password Attempts
Unit: 1 failed attempt Range:
Description:Counts the number of times there has been a failed password attempt.